Product Description

Olympus OmniScan X4 Phased Array Flaw Detector

Be Ready for What’s Next: OmniScan X4 Flaw Detector

A portable yet powerful solution, the speed and versatility of the OmniScan™ X4 multitechnology series boosts your productivity while increasing confidence in your assessments. Exploit its advanced phased array capabilities, efficient total focusing method (TFM), and innovative phase coherence imaging (PCI) to detect and interpret challenging flaws and secure the integrity of your assets by identifying damage earlier.

Proven to Perform, Trusted to Deliver

Each OmniScan X4 unit is a complete multitechnology inspection toolbox, enabling you to exploit multiple ultrasonic testing techniques. Leverage its detection and measurement capabilities to accurately identify and evaluate the severity of damage before it becomes critical, protecting welds, components, and assets most susceptible to cracking or corrosion.

Assess with Certainty Using PCI

Eliminate doubt through phase coherence imaging’s capacity to detect and accentuate historically difficult-to-detect flaws, including hook cracks and stress corrosion cracking (SCC). Use PCI to clearly distinguish individual flaws in colonies of fine cracks and characterize them with certainty.

3x Faster TFM Acquisition Rate

Obtain crisp TFM imaging at up to three times faster* acquisition rates than the predecessor model (X3 64) thanks to the OmniScan X4 series’ improved processing power. Exploit the increased speed and 128-element capacity of the OmniScan X4 64:128PR unit to perform TFM inspections with extended focusing capabilities.

Gain Instant Insights and Eliminate Inefficency

Twice the Confidence with Twin TFM and PCI

Exploit the individual attributes of PCI and TFM to thoroughly investigate the volume of welds from both sides simultaneously. Use two probes to scan the weld in one pass, displaying TFM and PCI results to compare, measure, and confirm your characterization of indications with efficiency and precision.

Engineered for Speed and Simplicity

Performing phased array, TOFD, TFM, and PCI is straightforward and intuitive on the OmniScan X4 series. Inspectors of any experience level can exploit these techniques with increased efficiency and more confidence utilizing the simple step-by-step scan plan and application presets.

Convenient Application Presets

Improve the learning curve and increase the reliability and consistency of inspections between operators with the OmniScan X4 application presets. Even low-level users and new users can produce an optimal PA or PCI configuration within minutes.

With options for corrosion and composite inspections, these preprogrammed parameters simplify scanning setups using HydroFORM™, FlexoFORM™, and  RollerFORM™ scanners, and you can adjust the settings as needed.

Ease Complex Configurations

The OmniScan X4 scan plan’s intuitive step-by-step 3D graphics ease your inspection setups, from the most basic to the most complex.

When setting up your raster scan plan, the scan axes can be customed named and you can create a datum reference point relative to the asset. These real-world references as well as the true orientation correction, greatly ease the creation of an intuitive schematic representation of the inspection data for your report.

Choose the Right Model for Your Application

Each model of the OmniScan X4 series has the capability to drive probes with a certain number of elements, offering varying focusing capabilities for different materials and thicknesses. Here is an overview of the types of applications that the four models are most proficient at performing. Contact us or your Evident representative for more details.

16:64PR
Excels at the following applications:
  • Corrosion monitoring
  • Pipeline integrity
  • Manual PA/TFM
  • TOFD
  • Small piping
16:128PR
Excellent mid-range model for:
  • Thin weld ( 25 mm)
  • Wind blade manufacturing
  • Aerospace flaw detection
32:128PR
Enables high-productivity weld inspection including coarse-grained materials:
  • Thick welds, up to ~75 mm
  • Austenitic/CRA
  • Occasional TFM
  • Oil and gas
64:128PR
Higher-productivity weld inspection in thicker, coarse-grained materials:
  • Very thick welds, ~100 mm (using a 64-element aperture to improve sizing accuracy)
  • Austenitic/CRA
  • Intensive TFM (HTHA)
  • Advanced oil and gas and power gen
  • FMC collection and application development

 

Specifications are listed for all models unless stated otherwise

General and Enclosure

Size 335 mm × 221 mm × 151 mm (13.2 in. × 8.7 in. × 5.9 in.)
Weight 5.7 kg (with 1 battery) for model 16:64PR
5.9 kg (with 1 battery) for models 16:128PR, 32:128PR, and 64:128PR
Onboard Storage 1 TB internal SSD storage. Maximum 25 GB individual file size. Storage extensible using external USB drive
Storage Devices SDHC and SDXC cards, or most standard USB storage devices
Wireless Wi-Fi® 6E and Bluetooth® 5.3 onboard
PAUT Connectors 1 PA connector, 2x UT channels (2 P/R connectors each)
Available Configurations and Groups OmniScan X4A – 64 :128PR : 8 groups
OmniScan X4A – 32 :128PR : 8 groups
OmniScan X4A – 16 :128PR: 8 groups
OmniScan X4B – 16 :64PR: 2 groups (PA, UT, or TFM) or a specific configuration of 2 PA groups + 1 TOFD
Drop Testing Drop-tested according to MIL-STD-810G
Ingress Protection Rating IP65 Certified (completely protected against dust and water jets from all directions (6.3mm nozzle))
Display 269 mm (10.6 in.) TFT LCD with resistive touch screen, 1280 × 768 pixels
Battery 2 hot-swappable Lithium-ion batteries included, 87 Wh each
Battery Life Minimum of 5 hours (using ISO18563 standard setup parameters)
Operating Temperature −10 to 45 °C (14 °F to 113 °F)
Storage Temperature −20 °C to 60 °C (−4 °F to 140 °F) (with battery inside)
−20 °C to 70 °C (−4 °F to 158 °F) (with no battery inside)

Inputs and Outputs

Ports 2x USB 3.1, 1x video out (HDMI), 1x SDHC memory card slot, 1x communication (Ethernet)
Encoders 2-axis encoder line (quadrature or clock/direction)
Digital Inputs and Outputs 4 digital inputs (TTL), 4 digital outputs (TTL) including one reserved for acquisition on/off
External DC Supply 18 VDC, circular 2.5 mm diameter connector, center-positive

General Ultrasonic Specifications

Effective Digitizing Frequency Up to 100 MHz; User-adjustable compression factor
Maximum Pulse Repetition Rate (PRF) Up to 20 kHz; Actual maximum PRF is often limited by physics
(the time of flight required to obtain the ultrasonic signals)
Maximum Number of A-Scan Data Points Up to 16,384
A-Scan Bit Depth 16 bits
Rectification RF, full wave, half wave+, half wave−
Video Filtering Smoothing (adjusted to the probe frequency range)
Filtering PA channel: selection of band-pass filters, high-pass filters, and averaging
UT channel: selection of low-pass filters, band-pass filters, high-pass filters, and averaging
Time-Corrected Gain (TCG) PA: 40 dB per step of min. 0.1 dB
UT: 100 dB per step of min. 0.1 dB
Maximum slope of 40 dB/10 ns
Supported Beam Types (Groups) Selection of phased array ultrasonics (PAUT) beam types (linear, sectorial, and compound), single ultrasonic beam (UT), time-of-flight-diffraction ultrasonics (TOFD), total focusing method (TFM), phase coherence imaging (PCI), full matrix capture (FMC), and plane wave imaging (PWI)
Raw Full Matrix Capture (FMC) Data Collection Available only with model 64:128PR when using the NDT Device API or the OmniScan Black Box onboard application used with external acquisition software

Acoustic Specifications

 

 

PA Channel UT Channels
Certification Calibration Certification ISO 18563-1:2022 EN22232:2020
  Pulse Width Adjustable from 30 ns to 1000 ns;
resolution of 5 ns (half period of bipolar pulse or duration of negative pulse)
Adjustable from 30 ns to 1,000 ns; resolution of 2.5 ns
  Pulse Shape Bipolar negative-positive square pulse Negative square pulse
Receiver Gain Range 0 dB to 80 dB; maximum input signal 900 mVp-p (full-screen height). 0 dB to 120 dB; maximum input signal 30 Vp-p (full-screen height)
  System Bandwidth 0.2 MHz to 26.5 MHz 0.25 MHz to 28.5 MHz

PAUT Specifications

OmniScan X4 Variant 64:128PR 32:128PR 16:128PR 16:64PR
Maximum Pulsing Aperture 64 32 16 16
Maximum Number of Receiving Channels 128 128 128 64
Number of Focal Laws 1024 maximum total (512 maximum per group)

FMC / TFM / PCI / PWI Specifications

OmniScan X4 Variant 64:128PR 32:128PR 16:128PR 16:64PR
Maximum Extended Aperture (FMC) 128 64 32 32
Maximum Aperture (PWI) 64 32 16 16
Maximum TFM or PCI Groups 4 4 4 2
Live TFM Envelope Yes – Actual Hilbert Transform
Image Resolution Up to 1024 × 1024 (1M points) for each TFM or PCI wave set
FMC Supported Wave Sets (TFM or PCI Modes) Pulse-Echo: L-L, T-T, and TT-TT
Self-Tandem: TT-T, TT-TTT, LL-L, LT-T, TL-T, TT-L, and TL-L
PWI Supported Wave Sets (TFM or PCI Modes) Pulse-Echo: L-L and T-T

Warranty Information

2 Year

Find Similar Products by Tag

Find Similar Products by Category

Write your own product review

Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!

Currency Converter

Choose a currency below to display product prices in the selected currency.

United States USD
United Arab Emirates AED
Australia AUD
Canada CAD
European Union EUR
British Indian Ocean Territory GBP

Add to Wish List

Click the button below to add the Olympus OmniScan X4 Phased Array Flaw Detector to your wish list.

You Recently Viewed...